Logo

Firewall (Wood)

Tested for Propagation of fire up to two hours by National Test House

  1. ASTME 119/ BS 476 (As per Pt. 20 and 24)
  2. IS: 162:1950

Basic safety dictates that any wooden structure is designed with appropriate fire protection systems to help save lives and other damage due to fire. Wood is flammable and helps spread fire very fast. Firewall offers spread of fire up to two hours which is more than sufficient time to get help.

Flame Retardant Paint (Wood)

Additional Product Information:

Application viscosity: Thixotropic / Ready to Use

Mix Ratio: Not applicable

Typical Film Thickness: 130 to 170 microns dry (single coat)
Required film thickness depends on fire ratings

Theoretical Coverage: 9(m2/lt) at 130 microns DFT.

Method of Application: Airless Spray, Brush, Roller.

Drying Information: Ambient Temperature (25°C)

Touch Dry: 2 Hours

Hard Dry: 4-5 Hours(Recoating Interval: Min. 5 hours)

Viscosity: 90 - 110

Approx. Weights: 1.3 ± .3kg. per ltr.

Shelf Life: 12 months from date of packing

Fire Rating Average Dry Thickness (Firewall)
30 min. 250 microns
60 min. 350 - 450 microns
120 min. 550 - 700 microns

In continuously improving technology there has been a swing towards the use of thin film intumescent coatings to achieve same traditional results.

Click Here to Watch How it works : Watch Demo